Extracting prog: 5m17.849010835s
Minimizing prog: 2h38m3.22909865s
Simplifying prog options: 4m51.629906432s
Extracting C: 2m18.997481714s
Simplifying C: 49m15.9806839s
extracting reproducer from 1 programs
testing a last program of every proc
single: executing 1 programs separately with timeout 30s
testing program (duration=30s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
single: failed to extract reproducer
single: executing 1 programs separately with timeout 6m0s
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program crashed: INFO: rcu detected stall in corrupted
single: successfully extracted reproducer
found reproducer with 12 syscalls
minimizing guilty program
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240))
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(0xffffffffffffffff, 0xaf01, 0x0)
r0 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(0xffffffffffffffff, 0x4004af07, &(0x7f0000000240)=r0)
ioctl$VHOST_SET_VRING_KICK(0xffffffffffffffff, 0x4008af20, &(0x7f0000000040)={0x1, r0})
ioctl$VHOST_SET_VRING_ADDR(0xffffffffffffffff, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(0xffffffffffffffff, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(0xffffffffffffffff, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(0xffffffffffffffff, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, 0x0, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, 0x0)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, 0x0, 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, 0x0)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, 0x0)
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, 0x0)
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, 0x0, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, 0x0)
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, 0x0, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, 0x0})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, 0x0)
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0x0, 0x0}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program did not crash
testing program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, 0x0)
program did not crash
extracting C reproducer
testing compiled C program (duration=6m0s, {Threaded:true Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in cfg80211_wiphy_work
a never seen crash title: INFO: rcu detected stall in cfg80211_wiphy_work, ignore
simplifying guilty program options
testing program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program crashed: INFO: rcu detected stall in corrupted
extracting C reproducer
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:4 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
simplifying C reproducer
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:true NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox: SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:false KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:false IEEE802154:true Sysctl:true Swap:false UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: no output from test machine
a never seen crash title: no output from test machine, ignore
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:true NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:true Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:true BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:true CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:true VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:true Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:true IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:false IEEE802154:true Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:false IEEE802154:false Sysctl:true Swap:true UseTmpDir:true HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in x64_sys_call
a never seen crash title: INFO: rcu detected stall in x64_sys_call, ignore
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:false IEEE802154:true Sysctl:true Swap:true UseTmpDir:false HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:false IEEE802154:true Sysctl:true Swap:true UseTmpDir:false HandleSegv:false Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in gc_worker
a never seen crash title: INFO: rcu detected stall in gc_worker, ignore
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:false IEEE802154:true Sysctl:false Swap:true UseTmpDir:false HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in do_idle
a never seen crash title: INFO: rcu detected stall in do_idle, ignore
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:false IEEE802154:true Sysctl:true Swap:false UseTmpDir:false HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
testing program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:false IEEE802154:true Sysctl:true Swap:false UseTmpDir:false HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program crashed: WARNING in rcu_check_gp_start_stall
validation run: crashed=true
testing program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:false IEEE802154:true Sysctl:true Swap:false UseTmpDir:false HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program crashed: INFO: rcu detected stall in corrupted
validation run: crashed=true
testing program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:false IEEE802154:true Sysctl:true Swap:false UseTmpDir:false HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
detailed listing:
executing program 0:
prlimit64(0x0, 0xe, &(0x7f0000000600)={0x9, 0x20000008b}, 0x0)
sched_setscheduler(0x0, 0x1, &(0x7f0000000080)=0x7)
prctl$PR_SCHED_CORE(0x3e, 0x1, 0x0, 0x2, 0x0)
r0 = openat$vhost_vsock(0xffffffffffffff9c, &(0x7f00000015c0), 0x2, 0x0)
ioctl$VHOST_SET_VRING_BASE(r0, 0xaf01, 0x0)
r1 = eventfd(0x0)
ioctl$VHOST_SET_LOG_FD(r0, 0x4004af07, &(0x7f0000000240)=r1)
ioctl$VHOST_SET_VRING_KICK(r0, 0x4008af20, &(0x7f0000000040)={0x1, r1})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000140)={0x0, 0x0, 0x0, &(0x7f0000000180)=""/53, 0x0, 0x60000})
ioctl$VHOST_SET_VRING_ADDR(r0, 0x4028af11, &(0x7f0000000280)={0x1, 0x1, 0x0, &(0x7f00000000c0)=""/87, &(0x7f0000000800)=""/90})
ioctl$VHOST_SET_MEM_TABLE(r0, 0x4008af03, &(0x7f0000000680)={0x1, 0x0, [{0x0, 0xfffffeac, &(0x7f00000001c0)=""/115}]})
ioctl$VHOST_VSOCK_SET_RUNNING(r0, 0x4004af61, &(0x7f0000000340)=0x1)
program crashed: INFO: rcu detected stall in corrupted
validation run: crashed=true
reproducing took 3h48m44.193104248s
repro crashed as (corrupted=true):
rcu: INFO: rcu_preempt detected stalls on CPUs/tasks:
rcu: (detected by 0, t=10502 jiffies, g=11225, q=244 ncpus=2)
rcu: All QSes seen, last rcu_preempt kthread activity 10502 (4294964434-4294953932), jiffies_till_next_fqs=1, root ->qsmask 0x0
rcu: rcu_preempt kthread starved for 10502 jiffies! g11225 f0x2 RCU_GP_WAIT_FQS(5) ->state=0x0 ->cpu=0
rcu: Unless rcu_preempt kthread gets sufficient CPU time, OOM is now expected behavior.
rcu: RCU grace-period kthread stack dump:
task:rcu_preempt state:R running task stack:27896 pid:16 tgid:16 ppid:2 task_flags:0x208040 flags:0x00080000
Call Trace:
context_switch kernel/sched/core.c:5258 [inline]
__schedule+0x150e/0x5070 kernel/sched/core.c:6866
__schedule_loop kernel/sched/core.c:6948 [inline]
schedule+0x165/0x360 kernel/sched/core.c:6963
schedule_timeout+0x12b/0x270 kernel/time/sleep_timeout.c:99
rcu_gp_fqs_loop+0x301/0x1540 kernel/rcu/tree.c:2083
rcu_gp_kthread+0x99/0x390 kernel/rcu/tree.c:2285
kthread+0x711/0x8a0 kernel/kthread.c:463
ret_from_fork+0x599/0xb30 arch/x86/kernel/process.c:158
ret_from_fork_asm+0x1a/0x30 arch/x86/entry/entry_64.S:246
rcu: Stack dump where RCU GP kthread last ran:
CPU: 0 UID: 0 PID: 6048 Comm: vhost-6047 Not tainted syzkaller #0 PREEMPT(full)
Hardware name: Google Google Compute Engine/Google Compute Engine, BIOS Google 10/25/2025
RIP: 0010:lock_acquire+0x16c/0x340 kernel/locking/lockdep.c:5872
Code: 00 00 00 00 9c 8f 44 24 30 f7 44 24 30 00 02 00 00 0f 85 cd 00 00 00 f7 44 24 08 00 02 00 00 74 01 fb 65 48 8b 05 44 91 25 11 <48> 3b 44 24 58 0f 85 e5 00 00 00 48 83 c4 60 5b 41 5c 41 5d 41 5e
RSP: 0018:ffffc900037076c0 EFLAGS: 00000206
RAX: 6db936dff3a79100 RBX: 0000000000000000 RCX: 6db936dff3a79100
RDX: 00000000fcf69c00 RSI: ffffffff8dc93c7b RDI: ffffffff8be247e0
RBP: ffffffff820c3e32 R08: ffffffff820c3e32 R09: ffff88801f3ec1c0
R10: dffffc0000000000 R11: ffffed1003e7d901 R12: 0000000000000001
R13: ffff88801f3ec1c0 R14: 0000000000000001 R15: 0000000000000246
FS: 0000555559b7c500(0000) GS:ffff8881259dc000(0000) knlGS:0000000000000000
CS: 0010 DS: 0000 ES: 0000 CR0: 0000000080050033
CR2: 0000000000000002 CR3: 00000000294a4000 CR4: 00000000003526f0
Call Trace:
gup_fast_fallback+0x23b/0x22d0 mm/gup.c:3204
set_bit_to_user drivers/vhost/vhost.c:2425 [inline]
log_write+0xc3/0x390 drivers/vhost/vhost.c:2451
vhost_update_used_flags+0x1ed/0x2b0 drivers/vhost/vhost.c:2582
vhost_enable_notify+0xb9/0x670 drivers/vhost/vhost.c:3227
vhost_vsock_handle_tx_kick+0x2cb/0xfe0 drivers/vhost/vsock.c:519
vhost_run_work_list+0x14e/0x1e0 drivers/vhost/vhost.c:454
vhost_task_fn+0x27c/0x430 kernel/vhost_task.c:49
ret_from_fork+0x599/0xb30 arch/x86/kernel/process.c:158
ret_from_fork_asm+0x1a/0x30 arch/x86/entry/entry_64.S:246
report is corrupted, running repro again
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:false IEEE802154:true Sysctl:true Swap:false UseTmpDir:false HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
report is corrupted, running repro again
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:false IEEE802154:true Sysctl:true Swap:false UseTmpDir:false HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
report is corrupted, running repro again
testing compiled C program (duration=6m0s, {Threaded:false Repeat:true RepeatTimes:0 Procs:1 Slowdown:1 Sandbox:none SandboxArg:0 Leak:false NetInjection:false NetDevices:false NetReset:false Cgroups:false BinfmtMisc:false CloseFDs:true KCSAN:false DevlinkPCI:false NicVF:false USB:false VhciInjection:false Wifi:false IEEE802154:true Sysctl:true Swap:false UseTmpDir:false HandleSegv:true Trace:false CallComments:true LegacyOptions:{Collide:false Fault:false FaultCall:0 FaultNth:0}}): prlimit64-sched_setscheduler-prctl$PR_SCHED_CORE-openat$vhost_vsock-ioctl$VHOST_SET_VRING_BASE-eventfd-ioctl$VHOST_SET_LOG_FD-ioctl$VHOST_SET_VRING_KICK-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_VRING_ADDR-ioctl$VHOST_SET_MEM_TABLE-ioctl$VHOST_VSOCK_SET_RUNNING
program crashed: INFO: rcu detected stall in corrupted
final repro crashed as (corrupted=true):
rcu: INFO: rcu_preempt detected stalls on CPUs/tasks:
rcu: (detected by 1, t=10502 jiffies, g=8989, q=51 ncpus=2)
rcu: All QSes seen, last rcu_preempt kthread activity 10502 (4294962127-4294951625), jiffies_till_next_fqs=1, root ->qsmask 0x0
rcu: rcu_preempt kthread starved for 10502 jiffies! g8989 f0x2 RCU_GP_WAIT_FQS(5) ->state=0x0 ->cpu=1
rcu: Unless rcu_preempt kthread gets sufficient CPU time, OOM is now expected behavior.
rcu: RCU grace-period kthread stack dump:
task:rcu_preempt state:R running task stack:27896 pid:16 tgid:16 ppid:2 task_flags:0x208040 flags:0x00080000
Call Trace:
context_switch kernel/sched/core.c:5258 [inline]
__schedule+0x150e/0x5070 kernel/sched/core.c:6866
__schedule_loop kernel/sched/core.c:6948 [inline]
schedule+0x165/0x360 kernel/sched/core.c:6963
schedule_timeout+0x12b/0x270 kernel/time/sleep_timeout.c:99
rcu_gp_fqs_loop+0x301/0x1540 kernel/rcu/tree.c:2083
rcu_gp_kthread+0x99/0x390 kernel/rcu/tree.c:2285
kthread+0x711/0x8a0 kernel/kthread.c:463
ret_from_fork+0x599/0xb30 arch/x86/kernel/process.c:158
ret_from_fork_asm+0x1a/0x30 arch/x86/entry/entry_64.S:246
rcu: Stack dump where RCU GP kthread last ran:
CPU: 1 UID: 0 PID: 0 Comm: swapper/1 Not tainted syzkaller #0 PREEMPT(full)
Hardware name: Google Google Compute Engine/Google Compute Engine, BIOS Google 10/25/2025
RIP: 0010:pv_native_safe_halt+0x13/0x20 arch/x86/kernel/paravirt.c:82
Code: cc cc cc cc cc cc cc 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 f3 0f 1e fa 66 90 0f 00 2d 33 0e 21 00 f3 0f 1e fa fb f4 48 ee 02 00 cc cc cc cc cc cc cc cc 90 90 90 90 90 90 90 90 90
RSP: 0018:ffffc90000197de0 EFLAGS: 000002c6
RAX: d8588d3afdcc9e00 RBX: ffffffff8197c6ba RCX: d8588d3afdcc9e00
RDX: 0000000000000001 RSI: ffffffff8daa9dc3 RDI: ffffffff8be247e0
RBP: ffffc90000197f10 R08: ffff8880b87336db R09: 1ffff110170e66db
R10: dffffc0000000000 R11: ffffed10170e66dc R12: ffffffff8fc3d070
R13: 1ffff11003b5eb70 R14: 0000000000000001 R15: 0000000000000001
FS: 0000000000000000(0000) GS:ffff888125adc000(0000) knlGS:0000000000000000
CS: 0010 DS: 0000 ES: 0000 CR0: 0000000080050033
CR2: 00007efe447700f0 CR3: 0000000031dfa000 CR4: 00000000003526f0
Call Trace:
arch_safe_halt arch/x86/include/asm/paravirt.h:107 [inline]
default_idle+0x13/0x20 arch/x86/kernel/process.c:767
default_idle_call+0x73/0xb0 kernel/sched/idle.c:122
cpuidle_idle_call kernel/sched/idle.c:191 [inline]
do_idle+0x1ea/0x520 kernel/sched/idle.c:332
cpu_startup_entry+0x44/0x60 kernel/sched/idle.c:430
start_secondary+0x101/0x110 arch/x86/kernel/smpboot.c:312
common_startup_64+0x13e/0x147